Характеристики

Пункт Показатель
Плотность 0.966
Показатель преломления(n20D) 1.501
Температура кипения, 190.9
Температура вспышки, 66.1
Чистота, % 99.0

Упаковка и хранение

Упаковка 200 кг бочка или IBC или ISOTANK
Хранение 20℃, 2 года.
Доставка Комнатная температура в Китае; может отличаться в других странах

Контактная информация

Чтобы получить образцы, цены или дополнительную информацию, позвоните нам по телефону 0086 25 51192301 напишите по адресу info@dimethyl-disulfide.net  или заполните следующую форму.

Мы ответим вам как можно скорее.

Tel: 0086 25 51192301
E-mail: info@dimethyl-disulfide.net

Общая информация

Frequently Asked Questions

Q: The physicial properties of Dipropyl disulfide?

A: Transparent colorless to pale yellow liquid; with a sulfur-like pungent smell, and a spicy pungent smell of onion and garlic. Almost insoluble In water, soluble in ethanol.

 

Q: The precautions when handling Dipropyl disulfide?

  1. Do not breathe vapor.
  2. Contact with skin and eyesshould be avoid.
  3. Wear appropriate gloves and goggles or mask.
  4. After accidental contact with eyes, rinse immediately and thoroughly with plenty of water and seek medical advice

 

Q: The emergency measures?

Inhalation: If inhaled the vapor, remove the victim to fresh air.

Skin Contact: Remove contaminated clothing, wash skin thoroughly and immediately with soapsuds and water. seek medical advice

Eye Contact: Lift the eyelids and rinse with running water or normal saline. Seek medical advice immediately.

Ingestion: Rinse mouth, do not induce vomiting. Seek medical attention immediately. Move the patient to a safe place. Consult a doctor. Show this chemical safety data sheet to the doctor on site.

 

Q: Fire-fighting measures?

A: Extinguish with water fog, dry chemical, foam or carbon dioxide. Avoid using direct water to extinguish the fire, which can make the possibility of splashing flammable liquid and spreading the fire. Firefighters must wear air-carrying respirators and full-body firefighting suits to fight the fire in the upwind direction. Move the containers from fire to open area if possible. Those present must evacuate the scene immediately if the container in the fire scene has changed color or sounds from the safety relief device. And isolate the accident scene, prohibiting irrelevant personnel from entering. Contain and treat fire fighting water afterwards to prevent environmental pollution.